Reusable FFP Mask
Washable full face seal made of comfortable TPE material which is gentle on the skin
Pleated filter technology: 260% more filter surface area
Significantly reduced breathing resistance
High filter capacity, longer usage time
DuraMesh®: strong and durable structure, keeps the mask in shape
ActivForm®: no nose clip needed
Loop strap with adjustable clip for quick, simple and safe on and off
Tested and certified to EN 149:2001+A1:2009
ActivForm®
Automatically fits to the face.
No manual adjustments by the user are necessary
DuraMesh®
Masks have a strong and durable structure.
Ventex®-valve
Starts to open even at low exhalation pressure and significantly reduces moisture and heat inside the mask.
Low breathing resistance
Pleated filter technology reduces inhalation resistance by
up to 50% whilst maintaining filtration performance.
Full face seal
3D face seal – like a rubber half mask – improves fit and
provides optimum wearing comfort.
R* – Reusable
The full face seal can be wiped clean and gives the
option of using the mask for more than one shift.
Adjustable Clip
Easy on & off; Adjustable strap for optimal fit and
wearer comfort.
Adjustable Strap
Makes it easier to take the mask on and off and to adjust to different head/neck dimensions.
Dolomite clogging test
Masks have passed the Dolomite clogging test, giving the
user better breathing resistance for longer
100% PVC-FREE
All Moldex products and packaging are completely free from PVC.
The Moldex Air Plus FFP-masks meet the requirements of EN149:2001+A1:2009
and are CE-marked in accordance with the requirements of European Directive
89/686/EEC. The IFA (0121) Germany is responsible for both type examination
(Article 10) and monitoring of production (Article 11B).
The products are manufactured in an ISO 9001 certified plant.
Filter Layer, Inner Shell, DuraMesh®: Polypropylene,
Ethylene-vinyl acetate (EVA)
Clip: Polyethylene
Cushion Seal: TPE
Head Strap: Polyester, Lycra
Ventex®-valve: Natural Rubber
T E S T I N G A C C O R D I N G T O N 149:2001+A1:2009
Total inward leakage
Ten test subjects perform a variety of exercises. During the exercises the
amount of test aerosol that penetrates the filter, face seal and valve are sampled. The total inward leakage of 8 out of 10 test subjects shall not exceed the following levels:
Max. total inward leakage 2%
Max. Filter penetration
The filter penetration after loading the filter with 120 mg paraffin oil according
to DIN EN149:2001+ A1:2009 shall not exceed the following levels:
Max. Filter penetration 1%
Flammability
4 respirators are passed through a 800°C (+/- 50°C) flame with a speed of
6 cm/s. After passing through the flame the respirator has to self-extinguish.
Breathing Resistance
The breathing resistance produced by the filter of the respirator is tested at an
airflow of 30 l/min and 95 l/min.
Max. breathing resistance according to EN 149
30 l/min – 1,0 mbar
95 l/min – 3,0 mbar
1. Pull strap to form a large loop.
2. Place respirator on chin and
pull loop over head tight to
the neck
3. Pull upper strap tight and
then place on back of head.
4. Ensure respirator fits secure
and comfortable.